8100-0114 & 8100-0114-LF SETUP PROCEDURE

8100-0114 & 8100-0114-LF   SETUP PROCEDURE  Updated 4/27/07

Step 1
Hold set for 5 seconds, til reads ModE)
Press SET 1 times to where it says LCK
change to 1000
Press set one time to return to operaters menu
Hold set for 5 sec, to read ModE
set & reset button 3 seconds
Cod has 0001
SET 6 times to MS
change to 1111
Press Set
Set and reset button for 2 seconds-go to Operators Menu

SET OPERATING MODE

Hold set 5 sec, to read ModE
Set to reflow, using up / down arrows
(Reflow is T1)
Press set one time to LCK
Set to 1000
Press set one more time to return to Operators Menu

Press set & reset button for 2 seconds to get to Parameter Setup
PARAMETER SETUP

Press “Set” to AL1
625 F or 300 C
Press “Set” to P
90 F or 60 C
Press “Set” to I
0004
Press “Set” to d
0001
Press “Set” to Ar
0010
Press “Set” to T
0002
Press “Set” to Pb
0000

Press “Set” to InP
0000 for APE Thermocouple (8100-0200-uni )
Press “Set” to UnIT
0000 for C or 0001 for F

Press “Set” to A S I
0001
Press “Set” to TLMT
0010
Press “Set” to CODE
Set to 0000
Press Set & reset for 3 sec to operators menu

Set Profile 1 Set Point/Ramp Time

Press “Set” two seconds to SVI
250 for C, 475 for F

Press “Set” to RMP
00.00
Press “Set” two seconds to Operators menu

SET ADD TIME

Set to ProF
0001
Set to Tim
00.00
Set to AddT
On
Set to ADDT
0010
Set to Operators Menu

SET PROFILE 2 SETTIME POINT/RAMP

Set to ProF
0002
Set two seconds to SV2
475 for F, 250 for C
Set to rmP2
01.00

Set key 2 sec to operators menu

SET PROFILE 3 SET POINT/RAMP TIME

Set to ProF
0003
Set 2 seconds to SV3
475 F or 250 C
Set to rmP3
03.00
Set 2 seconds to Operators menu

SET PROFILE 4 SET POINT/RAMP TIME

Set to ProF
0004
Set 2 seconds to SV4
475 F or 250 C
Set to RMP4
05.00

Set 2 seconds to Operators Menu
Press “Set” to ProF
0001
Press “Set” 4 times to operators Menu

SET RAMP/SOAK SET POINTS/TIMES

Press “Set” 5 sec till ModE
Change to ramp
Press “Set” twice to return to operators menu

SET PROFILE 1

Press “set” to Ptrn
0001
Press “Set” 2 Seconds to L1-1
250 C or 475 F
Press “Set” to T 1-1
01.00
Press “Set” to L 1-2
250 C or 475 F
Press “Set” to T 1-2
02.00
Press “Set” and set the rest of the settings in profile 1 to 0000
Press “Set” to EndP
0000
Press “Set” 2 seconds to Operators Menu

Set Profile 2

Press “Set” tp Ptrn
0002
Press “Set” 2 seconds to L2-1
525 F or 275 C
Press “Set” to T2-1
01.30
Press “Set” to L2-2
525 F or 275 C
Press “Set” to T2-2
02.00
Press “Set” to L2-3
And set the rest of profile 2 to 0000
Press “Set” to EndP
0000
Set 2 seconds to operator Menu

SET PROFILE 3

Press “Set” to Ptrn
0003
Press “Set” 2 seconds to L3-1
300 F or 150 C
Press “Set” to T 3-1
00.45
Press “Set” to L 3-2
300 F or 150 C
Press “Set” to T 3-2
01.00
Press “Set” to L 3-3
400 F or 200 C
Press “Set” to T 3-3
00.45
Press “Set” to L 3-4
400 F or 200 C
Press “Set” to T 3-4
00.45
Press “Set” to EndP
0004
Press “Set” 2 seconds to Operators Menu

SET PROFILE 4

Press “Set” to Ptrn
0004
Press “Set” 2 seconds to L4-1
475 F or 250 C
Press “Set” to T4-1
00.20
Press “Set” to L4-2
475 F or 250 C
Press “Set” to T4-2
01.00
Press Set and set the rest of Profile 4 to 0000
Press “Set” to EndP
0000
Press “Set” 2 seconds to Operator Menu

Press “Set” to Ptrn
0001

Press “Set” twice to STOP

SET TO MANUAL MODE

Press “Set” 5 seconds to ModE

Press up or down arrow to select Man Mode.

Press up and down arrow togethor to flash
“This resets the timer”

Setup is Complete